Insufflator Filter Tube
(Total 17 Products)-
Technical parameters: 1. Aeration medium: medical carbon dioxide (purity > 99.5%) 2. Interface pressure: 0-100bar 3. Working abdominal pressure: 3-25mmHg, inflation flow rate: 1-50L/min 4. Smoke intensity I/II is optional 5. Gas consumption...
-
Many conventional pneumoperitoneum machines have two weaknesses. First, constant pressure and accurate control can not be achieved, which will lead to the common complications of pneumoperitoneum: subcutaneous emphysema, hypercapnia and acidosis,...
-
Yao Ming Insufflation Tubing Set has strong compatibility, standard interface design, can be used with any standard piercing device in the world. Yaoming Insufflation Standard Filter Tube, using EPTFE liquid blocking high permeability membrane,...
-
Our company adheres to the principles of scientific development and people-oriented approach, boasting a comprehensive management team, robust technical team, stable sales team, and distribution channels.lt has established deep collaborations with...
-
Hunan Yaoming Medical Technology Co., Ltd. is a modern high-tech medical company and a wholly-owned subsidiary of Ningbo Yaoming Medical Technology Co., Ltd.The parent company is located in Ningbo City, Zhejiang Province, on the coast of the East...
-
In the case of continuous upgrading of the medical device industry, Yao Ming Medical has always been at the forefront of the exploration of minimally invasive surgical instruments and accessories (MISIA) in medical devices. Especially in the MISIA...
-
There are so many studies have shown that in laparoscopic surgery, high pneumoperitoneum pressure is likely to cause pneumoperitoneum complications such as hypercapnia and gas embolism. Due to the technical limitations of traditional...
-
Studies have shown that conventional pneumoperitoneum devices cannot autonomously regulate pressure,Therefore, there is a need for an improved pneumoperitoneum system that can provide low-pressure laparoscopic surgery without the complications...
-
Numerous studies have shown that in laparoscopic surgery, high pneumoperitoneum pressure is likely to cause pneumoperitoneum complications such as hypercapnia and gas embolism. Due to the technical limitations of traditional pneumoperitoneum system,...
-
UFOT-Y series filter tube group filter is composed of three cavities, collect water deodorization filtration and other functions in one, comprehensive filtration accuracy ≥99.9995%; By BFE bacterial filtration efficiency detection, the highest MPPS...
-
In the case of the continuous globalization and informatization of the medical device industry, Yao Ming Medical has always been at the forefront of the exploration of minimally invasive surgical instruments and accessories (MISIA) in medical...
-
Yao Ming Medical UF-50 series co2 insufflation machine can set 0-25mmHg abdominal pressure, and accurate control at 5-20mmHg(±2mmHg) working abdominal pressure. At the same time, the self-developed low abdominal pressure laparoscopic technology is...
-
In the case of the continuous globalization and informatization of the medical device industry, Yao Ming Medical has always been at the forefront of the exploration of minimally invasive surgical instruments and accessories (MISIA) in medical...
-
In the case of the continuous globalization and informatization of the medical device industry, Yao Ming Medical has always been at the forefront of the exploration of minimally invasive surgical instruments and accessories (MISIA) in medical...
-
The Yao Medical UF-50 series intelligent insufflator also reduces the risk of infection and other complications for patients. Its advanced technology ensures a clean and sterile environment, making the recovery process smoother and faster. The co2...
-
In the case of the continuous globalization and informatization of the medical device industry, Yao Ming Medical has always been at the forefront of the exploration of minimally invasive surgical instruments and accessories (MISIA) in medical...
-
Numerous studies have shown that in laparoscopic surgery, high pneumoperitoneum pressure is likely to cause pneumoperitoneum complications such as hypercapnia and gas embolism. Due to the technical limitations of traditional pneumoperitoneum system,...
insufflation tubing set
UFOT-Y series filter tube group filter is composed of three cavities, collect water deodorization filtration and other functions in one, comprehensive filtration accuracy ≥99.9995%;By BFE bacterial filtration efficiency detection, the highest MPPS filtration efficiency reached 99.999817%, by VFE virus filtration efficiency detection, the highest MPPS filtration efficiency reached 99.999732%, for smaller than MPPS (0.01μm) particle size filtration rate of nearly 100%.UFOTH series filter tube group based on UFOT-Y series smoke filter tube group, adding the adaptive gas injection heating technology developed by Yao Ming, can heat the carbon dioxide gas injected into the patient, ensuring that the carbon dioxide gas can reach 35℃ (±2°C) when entering the patient's abdominal cavity.EPTFE liquid blocking permeable membrane is used as the main filtration membrane of Yoming smoke exhaust filter pipe group, and the filtration accuracy is ≥99.9995%.Using Yao Ming patented technology, the combined heating and liquid deodorization technology, the exhaust filter cycle and the gas injection cycle are realized in the same filter.